Furnace not igniting: what the start-up tells you

When a gas furnace does not ignite, the burners never light or they light and quickly go out. The furnace follows a fixed start-up order, so watching where it stops points toward the cause. Some of the checks are safe for a homeowner. The parts that handle gas and flame are not.

If you smell gas, leave the house and call ATCO Gas at 1-800-511-3447 or 911 from outside. If a carbon monoxide alarm sounds, get everyone out and call 911.

How a modern furnace lights

Trane notes that furnaces made since about 2010 generally use an electronic igniter instead of a standing pilot light. On a call for heat, the draft inducer fan starts, the control board checks that air is moving through the venting, the igniter heats up, the gas valve opens, and a flame sensor must confirm the flame. If any step fails, the board shuts the gas off and may try again.

After several failed attempts the board usually goes into a lockout and stops trying until it is reset. Trane lists the common causes of that lockout as a dirty or defective flame sensor, a faulty igniter, gas supply pressure problems, overheating, a dirty filter, blocked vent pipes and a faulty control board.

Match what you see to the likely cause

What you noticeWhat it often points to
Nothing happens at allThermostat, power switch, breaker or a door switch. See the checks on the furnace not turning on page.
Inducer fan runs, then stops with no flameBlocked intake or exhaust pipe, or a venting or pressure switch problem.
Furnace clicks or hums but never lightsIgniter, gas supply or gas valve problem.
Burners light for a few seconds, then go outDirty flame sensor is the classic cause, since the board cannot confirm the flame.
Several tries, then a blinking light and no more attemptsIgnition lockout. The cause is still one of the items above.

Safe checks for a homeowner

  1. Set the thermostat to Heat and a few degrees above room temperature, and replace its batteries if it uses them.
  2. Confirm the furnace power switch is on and the breaker has not tripped.
  3. Replace a dirty filter. Trane says changing the filter is the only fix a homeowner should try for a hard lockout.
  4. On a high-efficiency furnace, clear snow, ice or debris from the white intake and exhaust pipes outside by hand. See furnace frozen exhaust pipe.
  5. Check that the gas valve near the furnace handle is in the on position. Do not force it, and do not go further than looking.

What is not a homeowner job

Trane says not to attempt to clean or replace the flame sensor yourself and to leave it to a professional. The same applies to the igniter, gas valve, pressure switch, control board and any gas pressure work. Lennox's own service guide describes measuring incoming gas pressure and manifold pressure with test equipment, which is the kind of work that needs training and tools. A technician will also read the control board codes, which tell them which step failed.

Older furnaces with a pilot light

If your furnace is older than about 2010, it may have a standing pilot light. Trane describes this as a constant flame that lights the gas when the thermostat calls for heat. If the pilot went out, the manufacturer's relighting instructions, usually on a label inside the furnace, are the only safe procedure. If the pilot keeps going out, stop and have it checked. ATCO Gas lists a pilot light that keeps going out as a warning sign alongside a yellow flame, as covered on furnace yellow flame.

Why you should not keep resetting it

A reset once to confirm the symptom is reasonable, and Trane mentions that some owner's manuals describe turning the power off and on to clear a lockout. Repeated resets are a different matter. The lockout exists because the furnace could not prove a safe flame, so forcing more attempts can hide an unsafe condition. If it locks out a second time, stop and book a diagnostic. Typical price ranges are on furnace repair cost in Edmonton.

Want numbers? Try the cost calculator or the repair-or-replace tool.

Frequently asked questions

Why does my furnace click but not ignite?

A click usually means the control board started the sequence but something stopped it, such as a failed igniter, a venting or pressure switch problem, or no gas reaching the burners. Check the outdoor vent pipes and filter, then call a technician if it still clicks without lighting.

Why does my furnace light and then go out after a few seconds?

The flame sensor proves to the control board that a flame is burning. If it is dirty or failing, the board shuts the gas off a few seconds after ignition, as a safety measure. Cleaning or replacing it is a technician repair.

Is it dangerous if my furnace will not ignite?

The furnace shutting off is its safety system working. The danger comes from a gas smell, soot or a CO alarm. If you notice any of those, leave the house and call ATCO Gas or 911.

How many times will a furnace try to ignite?

It depends on the model. Many try a small number of times and then lock out. The owner's manual or the label inside the furnace door usually explains the codes and the retry behaviour.

Sources

  1. Trane: furnace not igniting
  2. Trane: furnace hard lock out
  3. Lennox: furnace flame sensor basics
  4. ATCO Gas: carbon monoxide safety

Figures are guides, not quotes. Prices and rules change; confirm with your contractor and the City of Edmonton. Last reviewed November 2026.

Need heat back on in Edmonton?

Call now to reach a local technician, or send a quick request.

Call nowQuote