Which pipes are we talking about
A high-efficiency furnace usually has two white PVC pipes side by side or stacked on an outside wall. One brings in outdoor air for combustion and the other carries exhaust out. Some furnaces use one concentric vent with the exhaust inside and the intake around it, and some vent through the roof. A Calgary contractor, Purcell Heating, notes that the exhaust is usually the pipe giving off steam on a cold day, and suggests finding your pipes before winter so you know where to look.
Furnaces that draw combustion air from the furnace room and have only an exhaust pipe are not affected by intake blockage, according to another Calgary contractor, Advanpro.
Why they freeze or block
- Exhaust from a high-efficiency furnace is warm and moist, and in very cold air that moisture can freeze into frost and ice at the end of the pipe and slowly narrow it.
- Moist exhaust can be drawn back into a nearby intake pipe, where it condenses and freezes. Advanpro says the ice builds up over hours or days.
- Drifting or shovelled snow can pile against the wall and cover the pipes.
- Meltwater from the roof can drip onto the pipes and refreeze overnight.
- Summer insect screens left on the openings can collect frost quickly.
How the furnace reacts
A pressure switch inside the furnace confirms that air is moving through the venting before the burners are allowed to light. If a pipe is blocked, the switch will not close and the furnace stays off or shuts down. Advanpro says you may hear the inducer motor cycling on and off and see a pressure switch failed to close code. Purcell describes the same sequence: the inducer starts, then stops without lighting, or the furnace runs briefly and shuts off. That shutdown is a safety feature, not a breakdown.
What you can safely do
- Turn the thermostat down so the furnace is not trying to start while you work.
- Find both pipes outside and make sure you can reach them safely.
- With a gloved hand or soft brush, remove loose snow and frost from the openings and clear a space around them.
- Look into each opening with a flashlight. Light frost at the edge is fine. Solid ice deeper in the pipe is a job for a technician.
- Remove any insect screens for the winter.
- Go back inside, turn the thermostat up and watch one start-up. If it does not start within a few minutes, turn the furnace power switch off for about 30 seconds and back on once.
What not to do
- Do not use a shovel, ice chipper, hammer or scraper. Purcell warns that cold PVC is brittle and can crack or snap off at the wall.
- Do not try to break or remove ice that is frozen solid. Advanpro says to contact a qualified technician instead.
- Do not bypass, jumper or remove the pressure switch. It is there to stop the furnace running when exhaust cannot leave the house.
- Do not add a homemade cover, screen or pipe extension.
If it keeps happening
A pipe that freezes again and again is a design or installation question, not bad luck. Advanpro advises having a qualified technician inspect the venting to make sure exhaust is directed away from the furnace intake if blockages repeat. Vent changes belong with a technician and the furnace manufacturer's installation rules, not guesswork.
Other things that look the same
A furnace that starts and stops may also have a dirty filter, a flame sensor problem or another fault. If clearing the pipes did not help, read furnace short cycling and furnace not igniting. A furnace that runs but blows cool air is covered on furnace blowing cold air. For costs of a diagnostic and repair, see furnace repair cost in Edmonton.
Want numbers? Try the cost calculator or the repair-or-replace tool.