Does your furnace even have a pilot?
Carrier describes a pilot light as a small, continuously burning flame that ignites the main burner in older gas furnaces, typically those made before the mid-1990s. Bryant says standing pilots are found almost exclusively in older furnaces, and newer ones use electronic ignition with no flame burning all the time. Trane gives a somewhat different cutoff, noting that furnaces built before 2010 may still use a standing pilot. If your furnace is newer and clicks instead, read about a furnace that clicks but gives no heat.
Why a pilot goes out
- Worn or dirty thermocouple: Bryant calls this the most frequent cause, since grime or wear stops it from sensing the flame.
- Draft: Bryant lists vents, cabinet gaps and nearby doors that can blow the flame out.
- Blocked pilot orifice: dust or debris can partly clog the small gas opening.
- Low gas pressure: Bryant notes that this can make the flame sputter and go out.
- Malfunctioning gas valve: Carrier lists this among the causes of repeated outages.
How a thermocouple keeps the gas on
Carrier explains the sequence: the thermostat calls for heat, the gas valve opens, the pilot lights the burner and a thermocouple confirms the pilot is burning. If the flame goes out, the thermocouple shuts off the gas. That safety design is why a failing thermocouple makes the pilot appear to keep going out even when the flame itself looked fine.
Safe relighting basics
- Read the instruction label on the furnace first. Bryant stresses that procedures vary by model.
- Turn the thermostat to its lowest setting and turn the control to off. Bryant says to wait at least 5 minutes before introducing a flame.
- Hold the control in the pilot position while lighting, and keep holding for the time the manufacturer specifies. Bryant says some furnaces need about 30 to 60 seconds.
- If it goes out again, stop. Bryant warns that repeated attempts can hide a problem with a safety sensor or gas valve, and Carrier says to stop and call a technician after two or three failed tries.
What to do if it keeps happening
Bryant says a pilot that goes out more than once per heating season signals a problem that needs attention. Carrier lists a pilot that repeatedly goes out, a yellow, weak or irregular flame, and unusual noises as reasons to call a licensed HVAC technician. Having a technician replace the thermocouple, clean the pilot assembly and check gas pressure is a standard approach.
Bryant also recommends a carbon monoxide detector near the furnace, tested regularly. See our carbon monoxide guide.
Replace or repair an old pilot furnace?
If your furnace has a standing pilot, it is one of the older designs described above. If a technician finds the thermocouple, gas valve and heat exchanger all need attention, compare repair costs with a new unit. Our repair cost page and new furnace cost page help with that comparison.
Want numbers? Try the cost calculator or the repair-or-replace tool.