Furnace pilot light keeps going out: causes and next steps

A pilot light that will not stay lit is a classic problem of older gas furnaces. The reason is usually simple, such as a worn part or a draft, but the situation involves gas, so the safe steps matter more than speed.

If you smell gas, do not try to relight anything. Leave the house and call ATCO Gas at 1-800-511-3447 or 911 from outside. A yellow, weak or irregular flame, or a CO alarm, also means stop and call.

Does your furnace even have a pilot?

Carrier describes a pilot light as a small, continuously burning flame that ignites the main burner in older gas furnaces, typically those made before the mid-1990s. Bryant says standing pilots are found almost exclusively in older furnaces, and newer ones use electronic ignition with no flame burning all the time. Trane gives a somewhat different cutoff, noting that furnaces built before 2010 may still use a standing pilot. If your furnace is newer and clicks instead, read about a furnace that clicks but gives no heat.

Why a pilot goes out

  • Worn or dirty thermocouple: Bryant calls this the most frequent cause, since grime or wear stops it from sensing the flame.
  • Draft: Bryant lists vents, cabinet gaps and nearby doors that can blow the flame out.
  • Blocked pilot orifice: dust or debris can partly clog the small gas opening.
  • Low gas pressure: Bryant notes that this can make the flame sputter and go out.
  • Malfunctioning gas valve: Carrier lists this among the causes of repeated outages.

How a thermocouple keeps the gas on

Carrier explains the sequence: the thermostat calls for heat, the gas valve opens, the pilot lights the burner and a thermocouple confirms the pilot is burning. If the flame goes out, the thermocouple shuts off the gas. That safety design is why a failing thermocouple makes the pilot appear to keep going out even when the flame itself looked fine.

Safe relighting basics

  1. Read the instruction label on the furnace first. Bryant stresses that procedures vary by model.
  2. Turn the thermostat to its lowest setting and turn the control to off. Bryant says to wait at least 5 minutes before introducing a flame.
  3. Hold the control in the pilot position while lighting, and keep holding for the time the manufacturer specifies. Bryant says some furnaces need about 30 to 60 seconds.
  4. If it goes out again, stop. Bryant warns that repeated attempts can hide a problem with a safety sensor or gas valve, and Carrier says to stop and call a technician after two or three failed tries.

What to do if it keeps happening

Bryant says a pilot that goes out more than once per heating season signals a problem that needs attention. Carrier lists a pilot that repeatedly goes out, a yellow, weak or irregular flame, and unusual noises as reasons to call a licensed HVAC technician. Having a technician replace the thermocouple, clean the pilot assembly and check gas pressure is a standard approach.

Bryant also recommends a carbon monoxide detector near the furnace, tested regularly. See our carbon monoxide guide.

Replace or repair an old pilot furnace?

If your furnace has a standing pilot, it is one of the older designs described above. If a technician finds the thermocouple, gas valve and heat exchanger all need attention, compare repair costs with a new unit. Our repair cost page and new furnace cost page help with that comparison.

Want numbers? Try the cost calculator or the repair-or-replace tool.

Frequently asked questions

Can I relight the pilot myself?

Carrier says relighting may be appropriate for older furnaces with a standing pilot, as long as you follow the manufacturer instructions. If you smell gas or it will not stay lit, stop.

What is the most common reason a pilot will not stay lit?

Bryant calls a dirty or faulty thermocouple the most frequent cause, and Carrier says a worn thermocouple is the most common reason and usually an inexpensive repair.

How long should I wait before relighting?

Bryant says to wait at least 5 minutes after turning the control off. Always follow the label on your own furnace first.

Is a yellow pilot flame normal?

Bryant says a yellow or orange flame may indicate incomplete combustion and should be inspected. Carrier also lists a yellow flame as a reason to call a technician.

Sources

  1. Bryant Canada: furnace pilot light
  2. Carrier: furnace pilot light, how it works and common problems
  3. Trane: furnace not igniting troubleshooting

Figures are guides, not quotes. Prices and rules change; confirm with your contractor and the City of Edmonton. Last reviewed November 2026.

Need heat back on in Edmonton?

Call now to reach a local technician, or send a quick request.

Call nowQuote