Clicking that is normal and clicking that is not
FurnacePrices.ca says clicking while the furnace is simply heating up is normal. It becomes a concern when it is persistent, excessive, louder or changing, and the site ties that kind of clicking to the ignition system. So the question to answer is whether the burners ever light after the clicks.
Common reasons a furnace clicks without lighting
- Thermostat settings: Trane says to confirm the thermostat is on heat with a setpoint above the room temperature.
- Gas supply: the shutoff valve near the furnace may be closed. Trane says the knob or lever should be in the on position.
- Igniter: Trane notes furnaces made since 2010 use an electronic igniter, and a failed one needs professional troubleshooting.
- Flame sensor: a dirty or faulty sensor can prevent ignition because the furnace cannot confirm a flame.
- Dirty burners or a restricted filter: Trane lists both as causes that stop the sequence.
Step by step checks
- Check the thermostat: heat mode, setpoint above the indoor reading, and fresh batteries if it uses them.
- Confirm the furnace switch is on and the breaker has not tripped. If it has tripped, Trane advises not to reset it repeatedly and to call an HVAC professional.
- Look at the air filter and replace it if dirty. Trane suggests changing filters every 1 to 3 months.
- Check the gas shutoff valve near the furnace. If you cannot tell whether it is on, ask a professional rather than guessing.
- Give the furnace one more full cycle and note whether it clicks, lights briefly, or does nothing.
What the sequence tells you
A gas furnace has to light the burners and then confirm the flame before it keeps the gas flowing. Clicking with no flame suggests the sequence stalls at the lighting step. Burners that light for a few seconds and then go out suggest the flame is not being confirmed.
Trane describes the flame sensor as a safety device that detects flame and shuts off gas if none is found, and says cleaning or replacing it should be left to professionals.
Pilot-equipped furnaces
Trane says furnaces built before 2010 may use a standing pilot, and that a pilot that has gone out can be relit following the manufacturer guide. If yours has a pilot, see our pilot light guide for the safe steps and when to stop. Never relight if there is any smell of gas.
What not to do
- Do not open the furnace and clean burners yourself. Trane warns this may void the warranty and should be done by an HVAC company.
- Do not bypass safety switches or jumper controls.
- Do not keep cycling the thermostat dozens of times hoping it will catch. Repeated failed starts mean the problem is real.