Where CO comes from
- Improperly operating natural gas appliances, including furnaces, water heaters, dryers and ranges.
- Gas and diesel vehicles idling in an attached garage.
- Wood-burning fireplaces.
Symptoms of CO poisoning
- Headache and dizziness
- Fatigue and weakness
- Watering and burning eyes
- Nausea and vomiting
- Loss of muscle control
Alarms
- Install at least one CO alarm. ATCO recommends one per floor, and if you only have one, near the bedrooms.
- Write the expiry date on the alarm with a marker so you know when to replace it.
- Vacuum it monthly and replace the battery annually if it is battery powered.
- For new homes, the Alberta Building Code requires a CO alarm inside each bedroom or within 5 metres of each bedroom door when there is a fuel-burning appliance or an attached garage.
Prevention
Have your furnace and gas appliances checked regularly by a qualified technician, following the manufacturer's schedule. A yearly tune-up includes a safety and venting check. Keep intake and exhaust pipes clear of snow and ice.
Why a furnace can produce carbon monoxide
Burning natural gas needs the right mix of gas and air, and the combustion gases must leave the house through the vent. When air is restricted, a burner is out of adjustment or the heat exchanger is cracked, combustion is incomplete and carbon monoxide can form. A blocked flue or exhaust pipe can also push combustion gases back toward the living space.
Cold weather adds its own risks. Frost and drifting snow can cover the outdoor intake and exhaust pipes of a high-efficiency furnace, and a sealed-up house can starve an older furnace of air. This is one reason Alberta guidance stresses regular checks by a qualified technician rather than relying on the alarm alone.
Warning signs around the furnace itself
- Soot, scorch marks or black staining around the furnace or vent.
- A pilot or burner flame that looks yellow or orange and flickers instead of burning blue.
- Excess moisture on windows, or a stale, stuffy smell in rooms near the furnace.
- A furnace that keeps shutting down, or an alarm that sounds only when the furnace runs.
- Rust, water streaks or loose pipes on the vent connection.
What to do if the alarm goes off
- If anyone feels dizzy, nauseous or has a headache, get everyone, pets included, outside into fresh air.
- Call 911 from outside. Do not go back in to find the cause.
- If nobody has symptoms, press the reset button once and open a few windows.
- If the alarm sounds again, leave and call the fire department.
- Do not use the furnace again until a qualified technician has inspected it and the cause is fixed.
After an alarm: getting the furnace checked
A technician can inspect the burners, the heat exchanger, the venting and the combustion air supply. Ask for what they checked and what they found in writing. If the alarm was a false alarm or an expired unit, you still gain a safety check. If you want a technician to look at the furnace, you can request a visit.
Want numbers? Try the cost calculator or the repair-or-replace tool.